FluorLite® Protein Meter

Fast, True Protein Measurement for Dairy Permeates

Protein control is critical for membrane filtration systems. The FluorLite® Protein Meter delivers rapid, laboratory-grade protein measurements directly to the plant floor. Using fluorescence of the amino acid tryptophan, it measures true protein content with unmatched sensitivity and speed.
❖ True protein measurement
❖ Independent of non-protein nitrogen
❖ Rapid testing in 10 to 40 seconds
❖ Sensitivity down to 0.005 percent protein
❖ Automatic compensation for solids up to 10 percent
❖ No calibration required in the plant
❖ No consumables or disposables

How It Works

The meter excites tryptophan in dairy proteins with ultraviolet light at 280 nm and measures fluorescence near 350 nm. Because non-protein nitrogen does not fluoresce, the result is a true protein measurement, unaffected by NPN. Advanced optics automatically compensate for permeate solids from 1 to 10 percent, ensuring accuracy even in challenging conditions.

Simple Operation

A standard 50 ml sample is collected, poured into the stainless-steel sample cup, and positioned on the meter. Press “Measure,” and results appear within 10 to 40 seconds. No disposables are needed, no plant calibration is required, and a built-in thermistor corrects for temperature variations. Designed for both lab and at-line use, the instrument combines ease of use with robust construction.

Sensitivity that counts

The FluorLite Protein Meter detects protein concentrations as low as 0.005 percent and up to 0.5 percent, with readability to 0.001 percent. Validation mixes are available for quick confirmation of calibration. Results are consistent and repeatable, with a standard error of prediction below 0.01 percent protein.

Key benefits

  • True protein measurement, independent of non-protein nitrogen
  • Rapid testing in 10 to 40 seconds
  • Sensitivity down to 0.005 percent protein
  • Automatic compensation for solids up to 10 percent
  • No calibration required in the plant
  • No consumables or disposables

Designed for Today’s Dairy Operations

Introduced in 2023, the FluorLite® Protein Meter was created in response to industry demand for a reliable, easy-to-use protein measurement tool. With laboratory accuracy and plant-floor durability, it helps dairies monitor membrane performance, detect leakage, and make confident replacement decisions.

DOWNLOAD TECHNICAL SHEET  READ THE PRODUCT REVIEW

Headquarters

Reflectronics, Inc.
3881 Leighton Lane
Lexington, KY 40515